Before you invest, we simulate it.
Heat and mass transfer, fluid dynamics and finite element stress analysis. We start from the real loads of your operation —thermal, wind or dead load— to size equipment and structures before you buy or build.
Drag over the fluid to disturb it
Basis · equationsWhat the thermal and flow model solves
fε: vorticity confinement, restores the eddies a coarse grid dissipates.
Coils, switchgear and inverters are modeled as walls at a prescribed temperature.
Enforces ∇·u = 0 at every step (stable fluids method, semi-Lagrangian advection).
The simulation shows the qualitative behavior of the flow. The calculation report uses the energy balance with the equipment's actual loads.
Do you have equipment that overheats, an electrical room without ventilation or a process that doesn't cool enough?
Let's simulate your caseGround-mount PV structure under wind load
Reference case: fixed rack of a solar pumping system in Chihuahua. We compute the wind pressure, apply it to the finite element model, simulate gusts over time and justify every element: post, module rail, brace and anchors.
Building mesh…
Illustrative scenarios. In a real project we use the regional wind speed from the CFE Wind Design Manual for the site and return period.
2D frame model (Euler–Bernoulli) with the D + W combination, under pressure and suction; the envelope is reported. A36 steel (Fy = 250 MPa). Assumed anchors: 4 × ø16 mm A307 with a 200 mm lever arm; concrete and embedment length are checked to ACI 318 in the project calculation report.
Basis · equationsFrom wind to stress, step by step
Plane-stress Q4 elements, solved with preconditioned conjugate gradient.
fL = f·L(z)/vm. The time series is synthesized from 220 random-phase harmonics.
Newmark integration (average acceleration), ζ = 2 % for bolted steel.
If Pr/Pc < 0.2, use Pr/(2Pc) + Mr/Mc ≤ 1. Pc = Pn/1.67, Mc = Mn/1.67.
Every number in the panel comes from these equations with the inputs you move. A real project adds the full load combinations, the foundation and the connections.
40 HP motor–pump set · 1,760 rpm
This is how we diagnose in the field: waveform, FFT spectrum and shaft orbit. Each fault leaves a distinct signature; overall severity is evaluated against ISO 10816-3.
Basis · equationsHow the fault is diagnosed
Compared against the ISO 10816-3 zone limits for the foundation type.
Misalignment: 2X and axial; looseness: harmonics and 0.5X; bearing: non-synchronous peaks.
The signal is synthetic, but the processing is the same we apply to field measurements.
Synthetic signals with typical fault signatures, for presentation. Severity criterion: ISO 10816-3, group 2 (machines from 15 to 300 kW).
Ice banks and refrigeration
Redesign of a 5,000 L bank to cool product from 30 to 7 °C without relying on purchased ice.
FEA structural analysis
Stresses and deformations in supports, PV structures and mechanical components.
Ventilation of electrical rooms and inverters
Temperature of switchgear, transformers and inverters to avoid derating, alarms and failures.
Real-time 2D Navier–Stokes solver (stable fluids with vorticity confinement), for presentation purposes; it does not replace a project CFD study.
Colima · Jalisco · western Mexico
Do you have a project, a recurring fault or an upcoming audit?
Tell us what you need. We reply with a clear scope and a proposal fitted to what your operation requires.
Let's talk about your project.
We reply with a scope proposal and, if needed, a technical site visit.