Engineering firm · Colima, Mexico

Engineering that keeps industry running.

We are the electrical heart of your industry, your business and your home.

Specialists in photovoltaic systems

We design, build, maintain and certify electrical installations for plants, warehouses, businesses and homes, with a technical team that stays with each project from start to finish.

2+ MW installedNOM-001 · CFE
01 / WHO WE ARE

An engineering firm based in Colima, serving western Mexico.

At Summit Energy we turn electrical and energy problems into safe, efficient and fully documented installations.

We are a mechanical and electrical engineering team with more than 2 MW installed across different projects and regions, serving the food and beverage, steel, chemical, agribusiness, healthcare and retail industries. We combine field experience with analysis tools such as finite elements, thermal simulation and CFD, so decisions rest on data rather than assumptions.

We manage every project with PMBOK methodology: scope, cost, quality and risk under control, plus a technical deliverable your maintenance team can use the very next day.

ON SITEConfiguration and testing of a control panel at a plant.
01

Technical rigor

Every decision is backed by calculation, with NOM-001-SEDE-2012 as the design basis.

02

Accountability

We sign what we deliver and follow through from the site survey to project close-out.

03

Operational continuity

We plan outages and shutdown windows so your production stops no longer than necessary.

04

Evidence

Calculation report, as-built drawings, tests and a photo report for every job.

02 / MISSION AND VISION

A company committed to excellence.

For us, excellence is not a slogan: it is a method. It is measured in calculations that check out, installations that pass inspection the first time and documentation clients can use for the entire service life of their equipment.

MISSION

To design, build and maintain safe, efficient and fully documented electrical, energy and electromechanical installations that reduce our clients' risk and operating costs, with engineering backed by calculation, standards and evidence.

VISION

To be the leading electrical and energy engineering firm in western Mexico: industry's first choice when a project demands precision, operational continuity and technical backing.

To grow with a team of specialists, in-house measurement and simulation capability, and presence in the country's main industrial corridors, while keeping direct engineer-to-client service.

OUR COMMITMENTS
  1. Safety first

    No job starts without a risk assessment, lockout/tagout and proper protective equipment.

  2. Regulatory compliance

    Design and execution in accordance with NOM-001, the applicable NOM-STPS standards and CFE requirements.

  3. Verifiable quality

    Testing before energizing, thermography and a handover protocol the client reviews and signs.

  4. Transparency

    Clear scopes, no surprise costs and constant communication on the progress of every project.

  5. Energy efficiency

    Solutions that reduce consumption, losses and emissions, with their payback calculated.

  6. Continuous improvement

    Technical training, regulatory updates and a lessons-learned review at the close of every job.

04 / SERVICES

Eight disciplines. One quality standard.

01

Electrical design projects

Load schedules, protection, conductors, voltage drop and single-line diagrams per panel.

See service →
02

Photovoltaic systems

Grid-tied systems with CFE, solar irrigation pumping, performance reports and inverter service.

See service →
03

Industrial maintenance

Preventive and corrective programs for switchgear, substations and electromechanical equipment.

See service →
04

Compliance reports and calculations

NOM-001 verification, technical calculation reports and as-built surveys.

See service →
05

Electromechanical systems

Motors, standby generation, transfer switches, refrigeration and process equipment.

See service →
06

Engineering analysis and simulation

Finite elements, CFD and heat transfer to decide with data.

See service →
07

Reliability and predictive maintenance

Thermography, vibration, RCA and Pareto; OEE, MTBF and MTTR KPIs with CMMS.

See service →
08

Capacitor banks and power quality

Power factor correction, harmonics, efficiency and ESS storage.

See service →
05 / WHY SUMMIT

We think of everything.

Your investment, properly sized: no more and no less equipment than you need, alternatives compared by their return, and clear proposals from day one. The result is fewer shutdowns, fewer risks and better decisions for your operation.

Safety and compliance

Installations that meet NOM-001 and NOM-STPS, ready for audit and inspection.

Planned shutdowns, not surprises

Preventive and predictive maintenance that catches failures before they stop the line.

Measurable energy savings

Solar, reactive power compensation and efficiency, with a techno-economic return assessment.

Everything is documented

Calculation reports, single-line diagrams, load schedules and as-builts you can use to operate, expand and certify.

06 / SOFTWARE DEVELOPMENT

We also build the software your plant needs.

Portfolio case: DEICOCO Maintenance, the maintenance platform we designed and developed for an agribusiness plant in Tecomán, Colima.

0roles with permissions
0screens
100%works offline
  • Work orders and ISO 14224 failures

    The operator reports, the supervisor assigns, the technician records evidence and classifies the failure.

  • 3D plant view by area

    Status of processes, electrical room, boilers and PV system at a glance.

  • Equipment, preventive tasks and stores

    Three-level assets, history, scheduled maintenance, requisitions and purchasing.

  • Shipping and production

    Workflows for management, security, quality and production supervision.

  • The plant's own server

    Sync, folio numbers, files, emails and a daily summary; the data stays in the company.

Android · KotlinJetpack ComposePhone and tabletKtor server + PostgreSQLSHA-256 traceability
07 / OPERATIONAL CONTINUITY

When something fails, your plant keeps running.

Condition monitoring, redundant equipment, transfer to backup and immediate work orders. This is what a fault handled before it becomes a shutdown looks like.

Normal operation
Production RUNNING Availability 99.7 % Shutdowns avoided 0
CFE GRID GGENERATOR ATS POWER PANEL · 480 V T-100RECEIVING P-101 P-102 · BACKUP VT101 2.8 mm/s E-200 · COOLING TT200 T-300PROCESS LT300 PACKAGING SHIPPING → MONITORING · CMMS All equipment OK WORK ORDER · URGENT P-101 · high bearing vibration Assigned to mechanical technician · in progress

← Swipe to see the full process →

  1. 01Normal operationEquipment monitored in real time.
  2. 02Anomaly detectedThe vibration sensor raises an alert before the failure.
  3. 03Backup onlineThe redundant pump starts and a work order is issued.
  4. 04Grid failureThe transfer switch connects the generator in seconds.
  5. 05RestoredEquipment repaired, grid back to normal, no production stop.

Illustrative scenario.

08 / CASE STUDIES

Results you can measure.

Every project is delivered with data: what was installed, what was measured and what changed for the client.

+2 MW installed across projects and regions.

We want your company to be part of Mexico's energy transition.

Let's build your project
09 / PROJECTS

Featured projects.

Four jobs, four disciplines. Tap the thumbnails to walk through each project by stage, from rigging to handover.

10 / POWER QUALITY

Does your CFE bill carry a low power factor charge?

When power factor drops below 90 %, CFE adds a surcharge to every bill. A properly sized capacitor bank removes it, frees transformer capacity and reduces conductor losses. It is usually one of the fastest-paying electrical investments.

Quick calculator · estimate

200 kW
0.82
$80,000
Suggested bank (PF 0.97)—
Estimated current surcharge—
Estimated annual savings—

Illustrative calculation using the CFE surcharge formula for PF < 0.90. Actual sizing requires power analyzer measurement and a harmonic review.

Get your preliminary assessment

With this data we prepare a summary with the suggested bank, your surcharge and your savings, plus next steps.

  1. 01

    Measurement and diagnosis

    Power analyzer over days of real operation: demand, reactive power, harmonics and load profile.

  2. 02

    Bank engineering

    Fixed or automatic bank, in steps, with detuning reactors when harmonics are present. Protection and conductor sizing.

  3. 03

    Installation and commissioning

    Mounting, panel connection, controller setup and verification of the power factor achieved.

  4. 04

    Maintenance and follow-up

    Capacitor, contactor and temperature checks; bill tracking to confirm the savings.

No PF surchargeBonus on your billMore spare transformer capacityLower losses and heatingGrid Code requirement
Diagnose my power factor
12 / METHODOLOGY

A traceable process, from site visit to handover.

  1. STEP 01

    Site survey

    Technical visit, measurements and a record of the installation's actual condition.

  2. STEP 02

    Engineering

    Calculations, equipment selection and drawings to code.

  3. STEP 03

    Execution

    Construction with technical supervision, safety and coordinated outages.

  4. STEP 04

    Verification

    Electrical and functional tests before energizing.

  5. STEP 05

    Documented handover

    Calculation report, as-built drawings, photo report and recommendations.

Also for homes and businesses

Residential electrical service in Colima and Villa de Álvarez

Fault diagnosis, load centers, grounding, outlets and lighting, with the same technical criteria we apply in industry.

Book a visit
13 / CREDENTIALS

Credentials and standards we apply.

Training, standards and methodology behind every deliverable.

14 / STANDARDS

Regulatory framework

NOM-001

Electrical installations (utilization). Design, calculation and verification basis on every project.

Utility

CFE

Distributed generation interconnection, GDMTH tariffs, outage coordination and medium voltage.

Safety

NOM-STPS

029 electrical maintenance · 009 work at heights · 004 machinery · 020 pressure vessels and boilers · 017 PPE · 022 static electricity · lockout/tagout (LOTO).

Management

ISO

55001 assets · 14224 reliability · 17359 condition monitoring · 20816 vibration · 18434-1 thermography · 50001 energy · 45001 · 9001.

HuaweiSolisSchneider ElectricSiemensEatonCaterpillarKohlerCummins

Colima · Jalisco · western Mexico

Do you have a project, a recurring fault or an upcoming audit?

Tell us what you need. We reply with a clear scope and a proposal fitted to what your operation requires.

15 / CONTACT

Let's talk about your project.

We reply with a scope proposal and, if needed, a technical site visit.